Elevate Card has supported Dexter X machines as a payment option. This article will provide brief instructions on deploying the reader compatible with the target machine type.
Scope and Limitations
Country: All Countries based on Payment Service
Languages: English, Spanish, and French
Market: Laundry Market
Payment Types: Bank Cards / Cloud Cards / Value Cards / App / Coin & Bill / Campus Solution
Minimum Terminal Version Requirement: 4500.002.000.007
Manual Programming
Press the programming button on the machine panel for 2 seconds. The machine will enter the programming mode.
Manual Programming
The machine must be in idle mode for the manual programming menus to be accessed. Idle mode is when the machine is not actively running a cycle, and the vend price is displayed on the screen. To enter the manual programming mode, the top of the machine must be unlocked and lifted slightly. The programming button should be pressed for 1~2 seconds. The control should display the manual programming home page.
|
|
Singer Dryer & Stack Dryer | Washer |
Serial Mode Settings
In Vendor Portal→CCM→Profile Builder → Site Data, configure the settings in Site Data. You can refer to CCM - Profile Builder - Site Data for detailed instructions.

Log in market server KioCentral → Vendor Portal → CCM → Profile Builder → Dexter → Dexter X series → Washer/Single Dryer/Stacked Dryer.

Save the profile after the selection.

Pulse Mode Settings
In Vendor Portal → CCM → Profile Builder → Universal → Universal Pulse, configure the machine settings. You can refer to General Deployment Process for reference.
For Dexter X‑Series machines, you must enter the following specific values for the pulse settings:
Output Type: RelayPulse
Pulse Polarity: Idle Open
Output Pulse Gap: 300
Output Pulse Duration: 50