--- title: "How to Create a Universal Pulse Profile for Small Chassis Maytag" slug: "how-to-create-a-universal-pulse-profile-for-small-chassis-maytag" updated: 2025-11-17T17:58:29Z published: 2025-11-17T17:58:29Z canonical: "support.kiosoft.com/how-to-create-a-universal-pulse-profile-for-small-chassis-maytag" --- > ## Documentation Index > Fetch the complete documentation index at: https://support.kiosoft.com/llms.txt > Use this file to discover all available pages before exploring further. # How to Create a Universal Pulse Profile for Small Chassis Maytag **Environment** Maytag Small Chassis, MAT20, MHN33 --- **Resolution** > [!NOTE] > Note: > > We recommend using a **serial** profile for MAT20 or MHN33 but alternative option is the Universal Pulse profile. > > The Universal Pulse profile will pulse the laundry machine, simulating coin. Pulse cable on the back of the reader is required, along with the reader's jumper moved to **A** side. 1) Log into KioCentral and click on CCM **(Cloud Configuration Manager).** ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/Screenshot%202025-11-17%20112717.png?sv=2026-02-06&spr=https&st=2026-11-18T20%3A48%3A37Z&se=2026-11-18T21%3A48%3A37Z&sr=b&sp=r&sig=qB%2BmQIg9Rxg1cPHNdMeiqD0DoC%2F7oMR%2FRd3ZG08YKl0%3D) 2) Now, in the Profile Builder, Select **Universal** then **Universal Pulse** ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/image-75GX6717.png?sv=2026-02-06&spr=https&st=2026-11-18T20%3A48%3A37Z&se=2026-11-18T21%3A48%3A37Z&sr=b&sp=r&sig=XDqsWQiQRJG6u1SuX9tZv%2Ff4qgmlMl0o11tv9JzXZEw%3D) 3) Moving forward, you will be clicking on each tab starting with **Location** and providing the information for the configuration. This information must match the data previously entered in your vendors portal **Location Management** ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/image-7MPPVMFP.png?sv=2026-02-06&spr=https&st=2026-11-18T20%3A48%3A37Z&se=2026-11-18T21%3A48%3A37Z&sr=b&sp=r&sig=w0qbkF%2Bn6odbVePjvEOVczBInkon5WpSZuDW7SlPIes%3D) 4) In the **Machine Profile** tab, change the following. Machine Type: **Washer** Reader Mode: **Value** Pocket Configuration: **Single** ![machine profile uni pulse mat20 mhnn33.png](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/machine%20profile%20uni%20pulse%20mat20%20mhnn33.png?sv=2026-02-06&spr=https&st=2026-11-18T20%3A48%3A37Z&se=2026-11-18T21%3A48%3A37Z&sr=b&sp=r&sig=pwgpnnwGiPKnBNJH%2BdLBBj7Pk%2FxIIPSH3Npgr4Tjn6Y%3D) 5) The **Audio Visual** tab can be left as default. In the **Products, Pricing and Timing** tab, enter desired pricing and **Run Time as 35 mins** - **NOTE**: Time & Price must be set on the machine board as well. There are three different methods to get pricing: **Basic, Incremental, and Multi Pricing.** Fill out one tab and then click on the **Pulse** tab. ![Form displaying product pricing, timing, and transaction settings for a machine.](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/product timing uni pulse mat20 mhnn.png?sv=2026-02-06&spr=https&st=2026-11-18T20%3A48%3A37Z&se=2026-11-18T21%3A48%3A37Z&sr=b&sp=r&sig=QqERSzOYQ03bzRlO0JK%2BNFPq8wo1mn03tKgPoh7LxHM%3D) 6) Once completed, under the **Pulse** tab enter the following pulse setting for a Maytag Small Chassis (MAT20/MHN33)machine. - Output Type: **Coin Pulse** - Pulse Polarity: **Idle Closed** - Output Pulse Gap: **100ms** - Output Pulse Duration: **50ms** ![Settings for pulse output type, polarity, duration, and signal availability configuration.](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/pulse settings mat20 mhn33(1).png?sv=2026-02-06&spr=https&st=2026-11-18T20%3A48%3A37Z&se=2026-11-18T21%3A48%3A37Z&sr=b&sp=r&sig=bNLgQQCzQhQthU5Y9kPX%2B9BvWRV2itxlIVbvTuIcFpo%3D) 7) Proceed to fill out the following tabs as needed in the **Data Processing** tab. - For Surface readers (Prime, Connect, Solo using mobile app and/or laundry card): - Leave the **Data Processing** tab as Default. - Only for Ultra Readers (Credit Card): - Payment Gateway Option: **(from VAR sheet provided)** - POS ID: **(from VAR sheet provided)** - Aut Code: **(from VAR sheet provided)** - Auth Factor: **(from VAR sheet provided)** - Work Mode: **Retail (unless otherwise specified)** - WiFi SSID: **techtrex (unless otherwise specified)** ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/image-R3I9NFWG.png?sv=2026-02-06&spr=https&st=2026-11-18T20%3A48%3A37Z&se=2026-11-18T21%3A48%3A37Z&sr=b&sp=r&sig=XlCYahcz52%2FkYeK9pY0e%2B%2F3Klm6rRj4uKnbJsArN0yk%3D) 8) In the **Payment Types and Methods** tab, enter the desired payment options and change "SiteCodeCheck” to **Enable.** ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/image-KTRYN6H1.png?sv=2026-02-06&spr=https&st=2026-11-18T20%3A48%3A37Z&se=2026-11-18T21%3A48%3A37Z&sr=b&sp=r&sig=vsfGsGihkP1JDWFEcR0tw1%2B1g3R35XpB6NJvvDchDWc%3D) 9) Use the drop down to change ‘Profile” to “**Save Profile**”. Then enter the **CustomText** and click on the **SAVE** button. ![Profile Builder interface showing options to save and enter profile details.](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/save profile.png?sv=2026-02-06&spr=https&st=2026-11-18T20%3A48%3A37Z&se=2026-11-18T21%3A48%3A37Z&sr=b&sp=r&sig=BM4TnX0rP2MoECxaGTagJQVkkXm00hdfe3Aeih5MIi8%3D)