--- title: "How to create a Universal Pulse Profile for a Maytag MXR using PK130021" slug: "how-to-create-an-universal-pulse-profile-for-a-maytag-mxr-using-pk130021" updated: 2025-09-08T21:23:10Z published: 2025-09-08T21:23:10Z canonical: "support.kiosoft.com/how-to-create-an-universal-pulse-profile-for-a-maytag-mxr-using-pk130021" --- > ## Documentation Index > Fetch the complete documentation index at: https://support.kiosoft.com/llms.txt > Use this file to discover all available pages before exploring further. # How to create a Universal Pulse Profile for a Maytag MXR using PK130021 **Summary** How to Create a Pulse Profile for Maytag MXR washer using PK130021. --- **Issue** How to Create a Pulse Profile for Maytag MXR washer using PK130021. --- **Environment** Maytag MXR, Profit Plus, CCM --- **Resolution** | - The Universal Pulse profile will pulse the laundry machine, simulating coin. - Pulse cable on the back of the reader is required, along with the reader's jumper moved to B side. | | --- | - First let’s login into Washboard. - Once we’ve logged into the account’s Washboard, let’s search for CCM **(Cloud Configuration Manager).** ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/image-Y7I1OJZ7.png?sv=2026-02-06&spr=https&st=2026-11-18T20%3A51%3A57Z&se=2026-11-18T21%3A51%3A57Z&sr=b&sp=r&sig=8Tjht%2F5Tu6zs%2F7GAZPWqayXgx4rJLoo7wIG0hU6bEv0%3D) 1. Now, in the Profile Builder, Select **Universal** then **Universal Pulse** ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/image-75GX6717.png?sv=2026-02-06&spr=https&st=2026-11-18T20%3A51%3A57Z&se=2026-11-18T21%3A51%3A57Z&sr=b&sp=r&sig=MZVLdUM1QB0kOrvPCPAuhdsLVVaASiahR8Ss6ALLa%2FA%3D) 1. Moving forward, you will be clicking on each tab starting with **Location** and providing the information for the configuration. This information must match the data previously entered in your vendors portal **Location Management** ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/image-7MPPVMFP.png?sv=2026-02-06&spr=https&st=2026-11-18T20%3A51%3A57Z&se=2026-11-18T21%3A51%3A57Z&sr=b&sp=r&sig=WhPU%2BWb8MPoZJ%2FYGoWiq9zenVz0wYopGiFTGzYeZfpE%3D) 1. In the **Machine Profile** tab, change the following. - Machine Type: **Washer** - Reader Mode: **Value** - Pocket Configuration: **Single** ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/image-OX2WTY94.png?sv=2026-02-06&spr=https&st=2026-11-18T20%3A51%3A57Z&se=2026-11-18T21%3A51%3A57Z&sr=b&sp=r&sig=juAuJM%2FMfZqQK0K3Mxp5lY3q7rHvw5p01uVf2nNP43w%3D) 1. The **Audio Visual** tab can be left as default. 1. In the **Products, Pricing and Timing** tab, enter desired pricing. - **NOTE**: Time & Price must be set on the machine board as well. - Choose the basic pricing and enter the desired values. - Adjust the Run Time, average wash time is 25 mins. - Top-Off should be disabled. ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/image-YONMS3NM.png?sv=2026-02-06&spr=https&st=2026-11-18T20%3A51%3A57Z&se=2026-11-18T21%3A51%3A57Z&sr=b&sp=r&sig=wKXT3ccmt8HVN8rJmEcPKXegQniNHhqNb%2B7GE8XfMD4%3D) 1. Once completed, under the **Pulse** tab enter the following pulse setting for a Maytag MXR machine. - Output Type: **Coin Pulse** - Pulse Polarity: **Idle Open** - Output Pulse Gap: **100ms** - Output Pulse Duration: **22ms** ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/image-5NZA7WEZ.png?sv=2026-02-06&spr=https&st=2026-11-18T20%3A51%3A57Z&se=2026-11-18T21%3A51%3A57Z&sr=b&sp=r&sig=p94vUT%2FUlw3L1kwpxSdKSJEqG2tpN5NxpV91mM3T4og%3D) 1. Proceed to fill out the following tabs as needed in the **Data Processing** tab. - For Surface readers (Prime, Connect, Solo using mobile app and/or laundry card): - Leave the **Data Processing** tab as Default. - Only for Ultra Readers (Credit Card): - Payment Gateway Option: **(from VAR sheet provided)** - POS ID: **(from VAR sheet provided)** - Aut Code: **(from VAR sheet provided)** - Auth Factor: **(from VAR sheet provided)** - Work Mode: **Retail (unless otherwise specified)** - WiFi SSID: **techtrex (unless otherwise specified)** ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/image-R3I9NFWG.png?sv=2026-02-06&spr=https&st=2026-11-18T20%3A51%3A57Z&se=2026-11-18T21%3A51%3A57Z&sr=b&sp=r&sig=8oVG8TWjOm%2FtYnnK%2B7%2BAQVVahnKR%2BZKq%2BxT7yuiJ8j4%3D) 1. In the **Payment Types and Methods** tab, enter the desired payment options and change "SiteCodeCheck” to **Enable.** ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/image-KTRYN6H1.png?sv=2026-02-06&spr=https&st=2026-11-18T20%3A51%3A57Z&se=2026-11-18T21%3A51%3A57Z&sr=b&sp=r&sig=cNRDWhd3FjqWakLbhQTQQGhfZcVs9henMukjvcbINhI%3D) 1. Finally, save the profile. --- Note: The card reader’s AB jumper must be set to B side when using the (relay pulse) settings shown above. ![Back panel of a device showing various ports and connections for functionality.](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/VQM reader - Jumper on B with WH130021 plugged in(1).jpg?sv=2026-02-06&spr=https&st=2026-11-18T20%3A51%3A57Z&se=2026-11-18T21%3A51%3A57Z&sr=b&sp=r&sig=7Q7fl7R3rRdjQL0Ml1wBNGkRxnx6gHb5MJvLQq4DU0g%3D)