--- title: "MFR30PD Wiring - Route Settings" slug: "mfr30pd-wiring-revised-7-18-2022-route-setings" updated: 2025-09-11T18:32:37Z published: 2025-09-11T18:32:37Z canonical: "support.kiosoft.com/mfr30pd-wiring-revised-7-18-2022-route-setings" --- > ## Documentation Index > Fetch the complete documentation index at: https://support.kiosoft.com/llms.txt > Use this file to discover all available pages before exploring further. # MFR30PD Wiring - Route Settings **This document reviews MFR30’s board programming, wiring, and CCM Profile configuration** ## **1) MRF30 Board Programming:** Note: MRF30 Machine must be set to coin and debit mode (This ensures cycle status, otherwise reader will not sense cycle stopped) Programming the machine: Turn the Service key to switch from **RUN** mode to **SERVICE** In Service – SET-UP mode, the Main Menu Screen appears > “**Pricing Menu”** (2nd option listed) > “**General”** (Set-up of Pricing related functions) > Change payment selection to “**Coin & Card”** (2nd option listed) ## **2) MRF30 Harness Wiring:** Machine: MFR30PD PK: Pending Assignment of PK Number ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/mfr30pd-wiring-revised-7-18-2022---route-setings-image-o2wfq1z2.jpg?sv=2026-02-06&spr=https&st=2026-11-18T20%3A48%3A37Z&se=2026-11-18T21%3A48%3A37Z&sr=b&sp=r&sig=GgQ1hIw3Xar4ZA5R8txfLBOg3JkfyaIKKh0CTk7ojrU%3D) **Coin Connections - Remove machine’s original clear tab connections according to the following directions** ### ***Coin Out to Machine*** Machine green to harness green cable Machine blue to harness blue cable Machine red to harness red cable ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/mfr30pd-wiring-revised-7-18-2022---route-setings-image-5u3pofta.jpg?sv=2026-02-06&spr=https&st=2026-11-18T20%3A48%3A37Z&se=2026-11-18T21%3A48%3A37Z&sr=b&sp=r&sig=3EPem5A21m2sq41CLKukBbF4%2FyORttQM97Pgnlebq0s%3D) ### ***Coin In to Terminal*** Machine terminal red to harness green cable Machine terminal blue to harness black cable *Third connection on terminal – Machine's green cable with clear tab remains on terminal* Machine terminal yellow to harness white cable ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/mfr30pd-wiring-revised-7-18-2022---route-setings-image-fq7enzkm.jpg?sv=2026-02-06&spr=https&st=2026-11-18T20%3A48%3A37Z&se=2026-11-18T21%3A48%3A37Z&sr=b&sp=r&sig=vnnYbkwy71ap%2BucuKdMslVAEYGLwNhCPD%2FC3RtVTJNo%3D) Coin one – and two ### ***Power supply connection:*** The AC Power Adaptor (PS100007) with Brown & Blue pin connector is connected to WH120006 (Black & White Cable) ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/mfr30pd-wiring-revised-7-18-2022---route-setings-image-0sfc6m5a.jpg?sv=2026-02-06&spr=https&st=2026-11-18T20%3A48%3A37Z&se=2026-11-18T21%3A48%3A37Z&sr=b&sp=r&sig=pevr2C0QNUC28V9bAgJjw2HwrESFFiXugZji4cFM2qM%3D) WH120006 cable uses the blue splice tabs to tap into power on machine. Located on the top left side of the machine (shown in a red circle; see image below) Splice WH120006’ s black cable to machines' black cable Splice WH120006’ s white black cable to machines' white cable Serial connection (orange and black cable) from harness to Machine’s motherboard ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/mfr30pd-wiring-revised-7-18-2022---route-setings-image-rrvq6rfr.jpg?sv=2026-02-06&spr=https&st=2026-11-18T20%3A48%3A37Z&se=2026-11-18T21%3A48%3A37Z&sr=b&sp=r&sig=o165CYYC2CzY54HF9EhZ1EtIJH87mEv%2FMzcycrT6giA%3D) Harness’s card reader connection to mesh cable on back of reader The jumper on the *back of the card reader* needs to be changed from “**A**” to “**B**” side ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/mfr30pd-wiring-revised-7-18-2022---route-setings-image-s4jij9b7.jpg?sv=2026-02-06&spr=https&st=2026-11-18T20%3A48%3A37Z&se=2026-11-18T21%3A48%3A37Z&sr=b&sp=r&sig=wTqQy0eFobCiCNbHKxOC5pMgCZoe0Q87XjUXhQxRvqQ%3D) ## **3) MRF30 Profile:** Reminder: When using Common Pulse in CCM Creating the profile for MFR30 PD under CCM profile builder using the following settings: ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/mfr30pd-wiring-revised-7-18-2022---route-setings-image-bbb7wnjs.png?sv=2026-02-06&spr=https&st=2026-11-18T20%3A48%3A37Z&se=2026-11-18T21%3A48%3A37Z&sr=b&sp=r&sig=9akPr4XmBldhfeem1uxFtqyrik2s8f%2FYGIlzUI7mEHE%3D) CCM Profile > Machine Data > Common Pulse > Washer (Remember to also match the vend price on the board + profile) Pulse Width: **30** Pulse Rate: **100** Pulse Type: **Low**