--- title: "Troubleshooting Guide" slug: "prize-station-troubleshooting-guide" updated: 2025-02-12T23:50:58Z published: 2025-02-12T23:50:58Z canonical: "support.kiosoft.com/prize-station-troubleshooting-guide" --- > ## Documentation Index > Fetch the complete documentation index at: https://support.kiosoft.com/llms.txt > Use this file to discover all available pages before exploring further. # Troubleshooting Guide # Machine (TSD36 Compact) Troubleshooting | Electrical Error | | --- | | Fault | Possible Causes | Approach | | No power to the machine | - The power switch is not turned on. | Turn on the machine’s power switch. | | - The fuse has burned out | Check for short circuits in the machine, and replace the fuse with one of the same specifications. | | - The leakage protection switch trips. | Ensure there are no leaks in the machine, then press the reset button on the plug (with leakage protection). If reset button doesn’t work, replace the plug. | | - The power plug wire is damaged | Contact a professional to replace the power plug. | | - 110V power is not connected | Inspect the power supply lines to ensure the 110V power supply is properly connected. | | Not connected to the Internet | - No signal | Power off and restart the machine | | Ensure the antenna is installed correctly and the extension cable is intact. | | Confirm that the antenna is positioned on top of the machine. | | Try replacing the SIM card with one from a different operator. | | Move the machine to a different location; there may be no network signal in the current area. | | - Excessive traffic or downtime | Recharge the SIM card associated with the device. | | - Locked SIM Card | Contact support to unlock the SIM card. Note that the SIM card can only be bound to the specified machine. Using it in another device may result in it being locked. | | Lighting strip does not work | - The lighting strip is not turned on. | Turn on the lighting strip. | | - There is a loose contact in the lighting strip. | Check the sockets of the lighting strip and re-plug the sockets | | - The light strip is damaged. | Contact after-sales support to replace the lighting strip. | | Slot Error | | --- | | Fault | Possible Causes | Approach | | Spiral only rotates half-circle | - Slot mode is set to "Locker" | Need to change to "Spring" | | - Maybe the switch power supply damaged | Replace the switch power supply | | - Voltage is low | Check whether the output voltage of the switching power supply reaches 24V. | | The spiral rotates in the opposite direction | - Motor cable plug on the wrong port | Replace the motor cable plug on the back of the gearbox | | - Spiral direction does not match | Replace the spiral of another direction | | Single invalid slot (slot disappears in system) | - The cable is disconnected or has poor contact | Unplug and plug back in the gearbox (slot motor) cable, communication cable, and main board slot cable | | - The gearbox (motor) is damaged | Replace the gearbox (motor) | | - Mainboard or slot driving board is damaged | Replace the mainboard or slot driving board | | A whole row/column invalid (row/column disappears in system) | - Poor contact of the main board slot cable | Unplug and plug back in the main board slot cable | | - The slot tray and gearbox cable are loose and damaged | Unplug and plug back in the cable Replace the slot connection cable | | - Mainboard or slot driving board is damaged | Replace the mainboard or slot driving board | | Unable to select slot | - Slot failure has not been resolved. | Clear any failures or blockages in the cargo lane. | | Delivery failure | - The cloud background is inconsistent with the product code set in the machine. | Ensure that the cloud background and the machine's product encoding settings are aligned, or enable background synchronization. | | - The product size does not match the slot. | Replace the items with products that fit the slot, or adjust the slot to accommodate the size of the products. | | - The slot capacity setting is incorrect. | Clear any failures in the slot and reset it to the correct capacity. | # Ultra VQ-M Troubleshooting | Error Code List I | | --- | | Error Code | Description | Solution to try | | ER21 | Sync parameter to solo failed | Retry setup, if the problem persists RMA reader. | | ER22 | NMS Update failed | Check network settings, and retry NMS if needed. | | ER23 | Connect to NMS Server failed | Check network settings, and retry NMS if needed. | | ER24 | Download Configure file from the NMS Server failed | Check network settings, and retry NMS if needed. | | ER25 | Upload Configure file to NMS Server failed | Check network settings, and retry NMS if needed. | | ER26 | Upload saved log file to NMS Server failed | Check network settings, and retry NMS if needed. | | ER27 | Connect to TTI server fail | Retry the technician card, if the problem persists contact support. | | ER28 | Read Mr. Card error | Retry MSR magnetic swipe. | | ER29 | Verify CVC of MSR card error | Retry MSR magnetic swipe. | | ER30 | Verify uvid of MSR card error | Retry technician card, if the problem persists contact support. | | ER31 | The vendor ID of tech card error | Retry the technician card, if the problem persists contact support. | | ER32 | The vendor ID of tech card error | Retry the chip card, or try another card. | | ER33 | The swiped card is not tech card error | Retry the technician card, if the problem persists contact support. | | ER34 | Solo no communication with laundry machine | Retry setup, if the problem persists RMA reader. | | ER35 | Ultra one no communication with solo | Retry setup, if the problem persists RMA reader. | | ER36 | Auth POS fail | Check network connectivity verify Ultra POS parameters are correct, and retry authentication in Ultra functions using KLM, or via technician card. If problem persists contact support. | | ER37 | Laundry machine is busy now | Check status of the target machine. | | ER38 | Completion error | Check network connectivity, and verify correct master and backup units for Ultra segment are running. | | ER39 | Completion get parameter failed | Check network connectivity, and verify correct master and backup units for Ultra segment are running. | | ER40 | Completion set parameter failed | Check network connectivity, and verify correct master and backup units for Ultra segment are running. | | ER41 | Completion set information failed | Check network connectivity, and verify correct master and backup units for Ultra segment are running. | | ER42 | Completion failed | Check network connectivity, and verify correct master and backup units for Ultra segment are running. | | ER43 | Completion gets origin number fail | Check network connectivity, and verify correct master and backup units for Ultra segment are running. | | ER44 | Completion gets balance fail | Check network connectivity, and verify correct master and backup units for Ultra segment are running. | | ER45 | Completion updates balance fail | Check network connectivity, and verify correct master and backup units for Ultra segment are running. | | ER46 | Payment error 1 | Check network connectivity | | ER47 | Payment error 2 | Check network connectivity | | ER48 | Payment error 3 | Check network connectivity | | ER49 | Payment error 4 | Check network connectivity | | ER50 | Verify the mac value of the message failed | Check network connectivity, and verify correct master and backup units for the Ultra segment are running. Validate Ultra is in the correct segment. | | ER51 | MSR Card - offline no connectivity error | Check network connectivity. | | ER52 | Offline lost connectivity error | Check network connectivity. | | ER53 | Offline transactions do not support | Check network connectivity. | | ER54 | Offline transactions do not support chip card | Check network connectivity. | | ER55 | Cycle Changed, start machine failed | Users cannot change the cycle selection, or start the transaction again with proper cycle selection. | | ER56 | PIN pad not running | Retry setup, if the problem persists RMA reader. | | ER57 | Maytag machine response the Vend Price is 0. | Retry transaction. | | ER92 | WRONG SITE CODE | The site code in the card does not match the reader | | ER99 | BALANCE OVERFLOW | The balance exceeds the maximum value | | Error Code List II | | --- | | Error Code | Description | Solution to try | | OFFLINE NOT SUPPORTED FOR CONTACTLESS | Offline mode doesn't support contactless card | Try an MSR card or call for service | | PLEASE CALL FOR SERVICE | Offline mode doesn't support chip card | Try an MSR card or call for service | | Batch Nearly Full | Reader saved 498 transaction records which don't complete successfully | Waiting for daily settlement or doing manually settlement | | Batch Full | Reader saved 500 transaction records which didn't complete successfully, can't do a new transaction | Waiting for daily settlement or doing manual settlement | | Cloud Card Related Error Code | | --- | | Error Code | Description | Solution to try | | ANF | Account not found | Bind the card to the account | | E001 | Get price failed | 1. Check if the cloud card is bound to the account 2. Check if the account is registered | | E002 | Deduct money failed | 1. Check if the cloud card is bound to the account 2. Check the third-party response log | | E007 | Network is unavailable | Use KioSoft modem | | E008 | CJSON Parse (WB returns error text) | Close the cloud flare filter on OM | | E010 | Get Random Key failed | Restart the terminals at different times | | E013 | No Kiosoft modem | Use KioSoft modem | | E014 | No Modem | Use KioSoft modem | | E015 | Account is disabled | Go to server->Vendor Portal->Location Management to enable the account | | E016 | Other errors | / | | E017 | BALANCE IS NEGATIVE | Add funds to the account |