--- title: "Temperature Controller Advanced Menu" slug: "temperature-controller-advanced-menu" updated: 2026-09-24T09:23:27Z published: 2026-09-24T09:23:27Z canonical: "support.kiosoft.com/temperature-controller-advanced-menu" --- > ## Documentation Index > Fetch the complete documentation index at: https://support.kiosoft.com/llms.txt > Use this file to discover all available pages before exploring further. # Temperature Controller Advanced Menu ![](https://cdn.document360.io/43d8b414-8496-484c-a971-494dc8473827/Images/Documentation/image-06953TGU.png?sv=2026-02-06&spr=https&st=2026-11-18T21%3A01%3A43Z&se=2026-11-18T22%3A01%3A43Z&sr=b&sp=r&sig=MXiNy%2BA%2Fj16utC5%2BFCkRY66A49cvLoIb02%2FVcJnCCaw%3D) **3.1 Language** Support English and Chinese, default as English. **3.2 Temp. Symbol** The temperature symbol. You can choose from °C or °F. **3.3 Machine Model** For TF45E2, it should be set to Frozen. **3.4 Mode** Cooling/Heat/Off. For TF45E2, you should select Cooling mode. **3.5 Target** The target temperature set for machine cabinet inside, lowest temperature can reach -20°C (-4°F) in this model, recommend to set as -18°C or adjust based on actual situation. **3.6 Defog** to turn on/off the glass defogging (glass heating). The default setting is on. **3.7 Defrost Period** The time interval for defrost cycle. It is recommended to keep the default setting. **3.8 Defrost duration** The continuous time period to complete a defrost operation. It is recommended to keep the default setting. **3.9 Defrosting Temp** Defrost stop temperature. During the defrost process, temperature control probe on evaporator would detect actual temperature, when it reaches set temperature, defrosting stops (=compressor start to work). This parameter can be set between 0°C and 90°C, and the default setting is 20°C. **3.10 Temp. Controller Mode** To select operation mode for temperature controlling. ▸ Dual Mode: to set temperature on machine. When it is enabled, you can set the parameters of temperature controller on machine. ▸ Android Mode: to set temperature through Android tablet. ▸ Offline Mode: to set temperature exclusively on the temperature controller, not through the machine. **3.11 Calibrate Sensor:** It should be kept as default.