The reader now supports the Dexter C series. The deployment of this new feature follows the general deployment procedure outlined in a separate document. Since this series is a new machine type, new CCM profiles specific to these models have been provided. Please refer to the content below for more information.
Scope and Limitations
Country: All Countries based on Payment Service
Market: Laundry Market
Payment Types: Bank Cards / Cloud Cards / Value Cards / App / Coin & Bill / Campus Solution
Minimum Terminal Version Requirement: [UltraVX][GLOBAL][V2100.001.003.030]; [Ultra LX][GLOBAL][2300.001.001.016]
Create CCM Profile
You can create the CCM profile for your machine in the KioCentral system by navigating to Washboard => CCM => Profile Builder. Then, click on Machine Data => Dexter => C Series in sequence. The machine models will unfold, allowing you to select the specific one. Once selected, you'll see all the fields that need to be configured for the machine.
Although there are different machine models, the fields to be configured can be categorized into two types: Washer and Dryer. Please refer to the corresponding section for a description of the fields, depending on whether your machine is a washer or dryer.

Dexter C Series - Washer

Dexter C Series - Dryer
Dexter C Series - Washer
After selecting the specific washer model, you'll see the fields that need to be configured. When configuring the fields, clicking the input box will display the tooltip information for that field. Or you can refer to the table below for descriptions of these fields.
Before diving into the details, please note the following points:
The fields marked in the red box collectively constitute the total cycle time for a Normal Cycle.
The cycle time for the Super Cycle includes the fields in the blue boxes, in addition to those in the red box. Therefore, after enabling Super Wash, remember to define the extra fields to extend the total cycle time accordingly.
Field Name | Value Needed | Description |
---|---|---|
Vending Price | Numeric | Value range: 0-9999 Unit: cent Default Value: It varies for different machine models. |
Prewash Bath Cycle Time | Numeric | Default value: 0 Value range: 0-15 Unit: minute |
Prewash Spin Time | Numeric | Default value: 0 Value range: 0-10 Unit: minute |
Wash Bath Cycle Time | Numeric | Default value: 9 Value range: 3-15 Unit: minute |
Wash Spin Time | Numeric | Default value: 0 Value range: 0-10 Unit: minute |
Extend Wash Bath Cycle Time | Numeric | Default value: 0 Value range: 0-10 Unit: minute |
Rinse Bath Cycle Time | Numeric | Default value: 4 Value range: 0-15 Unit: minute |
Rinse Spin Time | Numeric | Default value: 1 Value range: 0-10 Unit: minute |
Final Rinse Bath Cycle Time | Numeric | Default value: 5 Value range: 3-15 Unit: minute |
Final Rinse Spin Time | Numeric | Default value: 6 Value range: 1-10 Unit: minute |
Extra Rinse Bath Cycle Time | Numeric | Default value: 0 Value range: 0-15 Unit: minute |
Extra Rinse Spin Time | Numeric | Default value: 0 Value range: 0-10 Unit: minute |
Super Wash | Drop-down Choice | Disable/Enable |
Super Wash Price | Numeric | It is only valid if the Super Wash parameter is configured as enabled. Default value: 100 Value range: 0-9999 Unit: cent |
Left Coin Value | Numeric | Default value: 25 Value range: 1-9999 Unit: cent |
Right Coin Value | Numeric | Default value: 100 Value range: 1-9999 Unit: cent |
Dexter C Series - Dryer
Once you've chosen the specific dryer model, the fields requiring configuration will be displayed. When configuring the fields, clicking the input box will display the tooltip information for that field. Alternatively, you can consult the table below for descriptions of these fields.
Field Name | Value Needed | Description |
---|---|---|
Vending Price | Numeric | Default value: 25 Value range: 0-9999 Unit: cent |
Cycle Time | Numeric | Value range: 1-99 Unit: minute Default value: It varies for different machine models. |
Free Vend Time | Numeric | Value range: 1-99 Unit: minute Default value: It varies for different machine models. |
Topoff Price | Numeric | Default value: 25 Value range: 1-9999 Unit: cent |
Topoff Time | Numeric | Value range: 1-99 Unit: minute Default value: It varies for different machine models. |
Max Topoff Time | Numeric | Default value: 99 Value range: 10-99 Unit: minute |
Left Coin Value | Numeric | Default value: 25 Value range: 1-9999 Unit: cent |
Right Coin Value | Numeric | Default value: 25 Value range: 1-9999 Unit: cent |