Feature Deployment Instructions: Supporting Dexter C Series

Prev Next

The reader now supports the Dexter C series. The deployment of this new feature follows the general deployment procedure outlined in a separate document. Since this series is a new machine type, new CCM profiles specific to these models have been provided. Please refer to the content below for more information.

Scope and Limitations

  • Country: All Countries based on Payment Service

  • Market: Laundry Market

  • Payment Types: Bank Cards / Cloud Cards / Value Cards / App / Coin & Bill / Campus Solution

  • Minimum Terminal Version Requirement: [UltraVX][GLOBAL][V2100.001.003.030]; [Ultra LX][GLOBAL][2300.001.001.016]

Create CCM Profile

You can create the CCM profile for your machine in the KioCentral system by navigating to Washboard => CCM => Profile Builder. Then, click on Machine Data => Dexter => C Series in sequence. The machine models will unfold, allowing you to select the specific one. Once selected, you'll see all the fields that need to be configured for the machine.

Although there are different machine models, the fields to be configured can be categorized into two types: Washer and Dryer. Please refer to the corresponding section for a description of the fields, depending on whether your machine is a washer or dryer.

Dexter C Series - Washer

Dexter C Series - Dryer

Dexter C Series - Washer

After selecting the specific washer model, you'll see the fields that need to be configured.  When configuring the fields, clicking the input box will display the tooltip information for that field. Or you can refer to the table below for descriptions of these fields.

Before diving into the details, please note the following points:

  • The fields marked in the red box collectively constitute the total cycle time for a Normal Cycle.

  • The cycle time for the Super Cycle includes the fields in the blue boxes, in addition to those in the red box. Therefore, after enabling Super Wash, remember to define the extra fields to extend the total cycle time accordingly.

Field Name

Value Needed

Description

Vending Price

Numeric

Value range: 0-9999

Unit: cent

Default Value: It varies for different machine models.

Prewash Bath Cycle Time

Numeric

Default value: 0

Value range: 0-15

Unit: minute

Prewash Spin Time

Numeric

Default value: 0

Value range: 0-10

Unit: minute

Wash Bath Cycle Time

Numeric

Default value: 9

Value range: 3-15

Unit: minute

Wash Spin Time

Numeric

Default value: 0

Value range: 0-10

Unit: minute

Extend Wash Bath Cycle Time

Numeric

Default value: 0

Value range: 0-10

Unit: minute

Rinse Bath Cycle Time

Numeric

Default value: 4

Value range: 0-15

Unit: minute

Rinse Spin Time

Numeric

Default value: 1

Value range: 0-10

Unit: minute

Final Rinse Bath Cycle Time

Numeric

Default value: 5

Value range: 3-15

Unit: minute

Final Rinse Spin Time

Numeric

Default value: 6

Value range: 1-10

Unit: minute

Extra Rinse Bath Cycle Time

Numeric

Default value: 0

Value range: 0-15

Unit: minute

Extra Rinse Spin Time

Numeric

Default value: 0

Value range: 0-10

Unit: minute

Super Wash

Drop-down Choice

Disable/Enable

When super wash is enabled, remember to define the extra cycle time for the related fields.

Super Wash Price

Numeric

It is only valid if the Super Wash parameter is configured as enabled.

Default value: 100

Value range: 0-9999

Unit: cent

The price defined in this field, along with the Vending Price, together constitute the Super Cycle price.

Left Coin Value

Numeric

Default value: 25

Value range: 1-9999

Unit: cent

Right Coin Value

Numeric

Default value: 100

Value range: 1-9999

Unit: cent

Dexter C Series - Dryer

Once you've chosen the specific dryer model, the fields requiring configuration will be displayed. When configuring the fields, clicking the input box will display the tooltip information for that field. Alternatively, you can consult the table below for descriptions of these fields.

Field Name

Value Needed

Description

Vending Price

Numeric

Default value: 25

Value range: 0-9999

Unit: cent

When it is set to 0, Free Vend will be activated.

Cycle Time

Numeric

Value range: 1-99

Unit: minute

Default value: It varies for different machine models.

Free Vend Time

Numeric

Value range: 1-99

Unit: minute

Default value: It varies for different machine models.

Topoff Price

Numeric

Default value: 25

Value range: 1-9999

Unit: cent

Topoff Time

Numeric

Value range: 1-99

Unit: minute

Default value: It varies for different machine models.

Max Topoff Time

Numeric

Default value: 99

Value range: 10-99

Unit: minute

Left Coin Value

Numeric

Default value: 25

Value range: 1-9999

Unit: cent

Right Coin Value

Numeric

Default value: 25

Value range: 1-9999

Unit: cent