Feature Deployment Instructions: Supporting Maytag MDB Machine

Prev Next

Elevate Card now supports the Maytag MDB Machine. The deployment of this feature follows the general deployment procedure outlined in General Deployment Process. This article will provide brief instructions on deploying the reader compatible with the target machine type.

Scope and Limitations

  • Country: All Countries based on Payment Service

  • Market: Laundry Market

  • Payment Types: Cloud Cards / Value Cards / App / Coin

  • Terminal Version Requirement: [Elevate Card][4500.003.001.003]

Create CCM Profile

  1. You can create the CCM profile for your machine in the KioCentral system by logging in to the market server KioCentral → Vendor Portal → CCM → Profile Builder  → Maytag → MDB → Washer.

Settings for a Maytag washer including cycle prices and options for operation.

Field Name

Value Needed

Description

Cycle 1 Base Price

Numeric

Default value: 100

Value range: 0-9999

Unit: cents

Cycle 2 Base Price

Numeric

Default value: 0

Value range: 0-9999

Unit: cents

Cycle 3 Base Price

Numeric

Default value: 0

Value range: 0-9999

Unit: cents

Cycle 4 Base Price

Numeric

Default value: 0

Value range: 0-9999

Unit: cents

Cycle 5 Base Price

Numeric

Default value: 0

Value range: 0-9999

Unit: cents

Cool Water Temp Adder Price

Numeric

Default value: 0

Value range: 0-9999

Unit: cents

Warm Water Temp Adder Price

Numeric

Default value: 0

Value range: 0-9999

Unit: cents

Hot Water Temp Adder Price

Numeric

Default value: 0

Value range: 0-9999

Unit: cents

Low Soil Level Temp Adder Price

Numeric

Default value: 0

Value range: 0-9999

Unit: cents

Medium Soil Level Temp Adder Price

Numeric

Default value: 0

Value range: 0-9999

Unit: cents

Heavy Soil Level Temp Adder Price

Numeric

Default value: 0

Value range: 0-9999

Unit: cents

Final Spin RPM

Numeric

Default value: 700

Value range: 700-950

Unit: RPM

Extra Rinse

Dropdown choice

Options: ON/OFF

Additional Wash Time

Numeric

Default value: 0

Value range: 0-5

Unit: minutes

Additional Rinse Time

Numeric

Default value: 0

Value range: 0-5

Unit: minutes

Value of Coin 1

Numeric

Default value: 25

Value range: 0-9999

Unit: cents or currency's lowest unit.

Value of Coin 2

Numeric

Default value: 100

Value range: 0-9999

Unit: cents or currency's lowest unit.

Currency Type

Dropdown choice

Options: Dollar/Other.

Pricing Base

Dropdown choice

Options: 25/50/500.
Only valid if “Other” currency was selected.

Display Price

Dropdown choice

Options: ON/OFF

Auto Clear Escrow Option

Dropdown choice

Options: Clear in 30 min/OFF.

Vending Safeguard

Dropdown choice

Options: Reject Bad Coin Pulses/Lock 30s on Bad Pulse.

Cycle Counting Option

Dropdown choice

Options: Enable/Disable.

Money Counting Option

Dropdown choice

Options: Enable/Disable.

  1. After setting up the profile to your needs, save it on the platform.