Temperature Controller Advanced Menu

Prev Next

3.1 Language

Support English and Chinese, default as English.

3.2 Temp. Symbol

The temperature symbol. You can choose from °C or °F.

3.3 Machine Model

For TF45E2, it should be set to Frozen.

3.4 Mode

Cooling/Heat/Off. For TF45E2, you should select Cooling mode.

3.5 Target

The target temperature set for machine cabinet inside, lowest temperature can reach -20°C (-4°F) in this model, recommend to set as -18°C or adjust based on actual situation.

3.6 Defog

to turn on/off the glass defogging (glass heating). The default setting is on.

3.7 Defrost Period

The time interval for defrost cycle. It is recommended to keep the default setting.

3.8 Defrost duration

The continuous time period to complete a defrost operation. It is recommended to keep the default setting.

3.9 Defrosting Temp

Defrost stop temperature. During the defrost process, temperature control probe on evaporator

would detect actual temperature, when it reaches set temperature, defrosting stops (=compressor start to work). This parameter can be set between 0°C and 90°C, and the default setting is 20°C.

3.10 Temp. Controller Mode

To select operation mode for temperature controlling.

▸ Dual Mode: to set temperature on machine. When it is enabled, you can set the parameters of temperature controller on machine.

▸ Android Mode: to set temperature through Android tablet.

▸ Offline Mode: to set temperature exclusively on the temperature controller, not through the

machine.

3.11 Calibrate Sensor: It should be kept as default.