Click the tab KioSoft> Airpump>EEM> Advanced Options in sequence then all parameters relating to Air pump will be shown. Define the parameters as needed and you can refer to the table below for descriptions of the fields required.
Field Name | Value Needed | Description |
Error Beep for SSUT | Drop-down choice (Enabled / Disabled) | Not Applicable This is used for Self SetUp Test. When doing SSUT, if this feature is enabled, the reader will keep beeping until the SSUT is passed. |
Coin Value | Numeric | Not Applicable Defines the coin value accepted by the machine. Unit is cent. Default value is 25. |
Vend Discounts (Washer Discount/ Dryer Discount) | Numeric | Not Applicable |
EEM Serial Number | Numeric | Input the Serial Number of EEM. 4 bytes in hex number. |
Air price | Numeric | Defines the air price to be charged for the air time defined in the next field “Air time”. Unit is 25 cents so the value input here means the number of 25 cents charged for the defined air time. |
Air time | Numeric | Defines the corresponding air time provided for the air price previously defined in the field “Air price”. Unit is 10 seconds so the value input here means the number of 10-second air time provided for the defined air price. Range is 0~255. |
Vac price | Numeric | Defines the vacuum price to be charged for the vacuum time defined in the next field “Vac time”. Unit is 25 cents so the value input here means the number of 25 cents charged for the defined vacuum time. |
Vac time | Numeric | Defines the corresponding vacuum time provided for the vacuum price previously defined in the field “Vac price”. Unit is 10 seconds so the value input here means the number of 10-second vacuum time provided for the defined vacuum price. Range is 0~255. |
Coin1 Properties Byte 1 | Drop-down choice (Quarter/Loonie) | Defines the currency value accepted by the coin device 1. |
Coin1 Properties Byte 2 | Drop-down choice (No action/Air/Vac) | Defines to which machine the coin device 1 is connected. |
Coin2 Properties Byte 1 | Drop-down choice (Quarter/Loonie) | Defines the currency value accepted by the coin device 2. |
Coin2 Properties Byte 2 | Drop-down choice (No action/Air/Vac) | Defines to which machine the coin device 2 is connected. |
Counters Quarters Total | Numeric | Defines the maximum value of quarters that the user can insert for one machine start. Range is 0~9999. |
Counters Loonies Total | Numeric | Defines the maximum value of Loonies that the user can insert for one machine start. Range is 0~9999. |