How to wire an ADC Phase 5 Single Machine (PK150005)

Prev Next

Issue

How to wire an ADC Phase 5 Single Machine (PK150005)


Environment

ADC Phase 5 Single Machine


Resolution

Part Number

Part Name

Items Included

PK150005

ADC Phase 5 Dryer Kit

  • WH150009-ADC Phase 5 Single and Stack Reader Cable

  • WH150006-ADC Stack Monitor Cable (not used with ADC Single)

  • AS110043-Dexter Status Box

  • AS110060-Plus Cash, Nylon Tie (x3)

  • WH150007-ADC Phase 5 Single Monitor Cable

  • FS000002-0.250" Tap Splice (x4)


Parts Illustrations

WH150009 ADC Phase 5 Single and Stack Reader Cable

WH150007 ADC Phase 5 Single Monitor Cable

AS110043 Dexter Status Box (without cables)


Status Box Connections

Start by connecting WH150009’s P4 connection to the status box (AS110043). Then WH150007’s P1 connector to the status box.


Motor Relay Connections

Find the machine’s motor relay, see images below for visual reference:

Example: Wiring diagram of an ADC phase 5

Example: Motor relay coil connections on ADC Phase 5

Diagram showing coil connections and labels for ten motors with L1, L2, T1, T2.

Connect the blue P2 T-Tap from WH150007 to the blue wire on the machine’s motor relay. Then, connect the white P3 T-Tap from WH150007 to the green wire on the motor relay.


Coin Drop Connections

Identify where the coin drop is connected to the control board. Disconnect the coin drop from this connection point and connect the WH150009's P3 connector in its place. Then, connect the WH150009's P2 connector to the coin drop.

ADC Machine Diagram

Partial diagram of WH150009, focused on coin connections

Diagram showing a computer board and coin acceptor with labeled components.


Power Connections

Locate the 24 VAC connections near the machine’s transformer. Then connect the WH150009’s P5 wire to the machine’s YELLOW wire and connect the WH150009’s P6 wire to the machine’s GREEN wire.

ADC Machine Diagram

Partial diagram of WH150009, focusing on power connections

Example: Wiring diagram of an ADC phase 5

Electrical diagram showing connections and components for an electric oven system.


Card Reader Connection:

Connect the WH150009’s P1 to the KioSoft card reader’s data cable.


Card Reader Jumper:

Readers out of the box, will have the jumper set to “A” side. When using ADC, this must be moved over to the “B” side.

The jumper’s pins need to be horizontal and not vertical. The jumper has two parts, each with two pins. Make sure both pieces are moved closer to the right “B” side. Example image above shows an Ultra LX reader’s jumper moved to the “B” side.