Document Overview
The objective of this document is to cover how to setup a Wascomat Compass controlled machine with and without coin. This document goes over the wiring of a Wascomat Compass with connection kit PK160037. Additionally, this document explains how to create a the machine’s profile in the Cloud Configuration Manager, used for programming the KioSoft card reader.
Parts List
Part Number | Part Name | Items Included |
PK160037 | Wascomat / Electrolux W/E Connection Kit with Coin |
|
Harness Connections Illustration
WH160010 Serial Box Interface Cable with Wascomat Compass Coin
WH160001 Compass Wire Harness
AS160002 Serial Interface Box
Before Installation
PLEASE UNPLUG LAUNDRY MACHINE
PRIOR TO INSTALLATION OF HARNESS
Wiring Instructions
Serial Connection
Place 7-pin Serial connection from WH160010 into the top of AS160002 Serial Module.
Then place 10-pin connection from WH160001 to the bottom of the AS160002 Serial Module
Take WH160001’s 4-pin blue cable (port maybe printed as D-BUS) into the RS232 on board. NOTE: Do not place, the 4-pin cable into D-BUS on the machine board.
Coin Connection
(NOTE: Skip if not using coin, extra connection will not affect the machine.)
Remove the machines coin drop cable. Then using the blue taps provided, splice the machine’s coin drop
cable into the matching colors on WH111005
Connect WH111005 to coin cable (green, black, brown and white) on WH160010
Power Connection
REMINDER – Please make sure the laundry machine is power down before proceeding.
Then take WH160001’s female 2-pin, black and white, cable into the AC Adapter’s 2-pin male connection
Arrange AC adapter wires in machine, leading towards the back of the machine.
Wascomat Compass Wiring Instructions ®2022 KioSoft Technologies
Pull AC adapter’s cable through the hole in the back of the machine.
Remove the four screws, circled in image below, off the machine’s back panel.
With AC adapter cable through the hole, plug WH120006 into the AC adapter.
NOTE: Please consult the Owner’s Manual before connecting WH120006 & PS100007 Power Adaptor to your laundry machine. Depending on the machine model and voltage, connections may vary. PS100007 Power Adaptor accepts a wide input from 100-240 V – 50-60HZ 0.8A and output of 12V.
For example: Reference images shown below are on a Wascomat W720cc. In this example, WH120006’s white cable is connected to neutral and the black cable to L1.
Creating a profile
Under CCM, in the Profile Builder: Select the following for Machine Data
Select “Wascomat”
Select Machine Control Type as “Compass”
Select Machine type:
After, click on "Advance Options" and configure machine fields (vend price, time, etc.,) as needed.
Once machine values are configured, click on “Site Data” and enter location information.
Site Code and Location ID must match the location in Location Management on Laundry Portal
For Location ID and Room#, you should enter the ones that you created previously
See image below regarding Site Data’s field values.
Location ID
Site Code
Room Number
Each room will get its own profile.
Non-Network
This should be enabled any time a modem is not present in the room.
Card Holder
Hide Label
This will hide the machine number on Connect and Elevate readers
If applicable, for Payment Options, ensure you select the payment methods for the desired location.
Finally, select “Save Profile” from the drop-down menu and click “Save”
Enter “Custom Text” for easier identification in the KioSoft Laundry Manager Application.
Example of Custom Text Label: Location Name RM1 COMPASS Dryer [225]