This document provides wiring instructions for Dexter C‑Series machines using PK1A0012, covering washers, single dryers, and stacked dryers. Please follow the steps below to complete the wiring.
Scope and Limitations
Reader supported: All readers
Wiring Instructions for Serial Mode
Parts List
Part Number | Part Name | Items Included |
|---|---|---|
PK1A0012 | Dexter C-Series Serial Kit | WH1A0015 - Dexter C-Series Serial Reader Harness AS1110148 - Laundry Serial Interface Module WH1A0016 - Dexter C-Series Serial Machine Harness PS100007 - Power Adapter, 12V for CleanReader WH111004 - 120Vac Long Power Cable, Universal 2 x PP000003-Wire Tap Splice |
Connections Illustrations
The actual color of the wires differ from the picture. Please refer to the wire colors shown in the diagram.
| |
WH1A0016 - Dexter C-Series Serial Machine Harness | WH1A0015 - Dexter C-Series Serial Reader Harness |
| |
The wiring diagram of Dexter C-Series - Serial Mode | |
Connection of the Laundry Serial Interface Module
For Elevate Card (versions later than 4500.002.000.007), Elevate Touch, Elevate Solo, and Ultra LC/LW/LT, the Laundry Serial Interface Module is optional. If not used, connect the WH1A0016 directly to the reader.
Connect the 10-pin end of WH1A0016 to the Laundry Serial Interface Module.
|
Connect the other end of WH1A0016 to P10 on the machine control board for the dryer, and to P9 on the control board for the washer.
|
|
Dryer Control Board | Washer Control Board |
Connect the 6-pin end of WH1A0015 to the Laundry Serial Interface Module, and the other end to the reader.
|
|
Power Connection
Connect the 2-pin end of WH1A0016 to the power adapter. And connect the power adapter to the 2-pin end of WH111004.
|
|
Tap-splice the black wire of WH111004 to the machine’s 120V HOT, and the white wire to its 120V NEUTRAL.