Wiring Instructions - Whirlpool Electromechanical Dryer

Prev Next

Document Overview

The objective of this document is to cover how to setup a Whirlpool laundry machine with and without coin usage. This document goes over the wiring of a Whirlpool machine with connection kit PK140002.


Parts List

Part Number

Part Name

Items Included

PK140002

CleanReader Installation Kit  -

Whirlpool Electromechanical - Dryer (excl. Ultra)

  • AS140007 Whirlpool Dryer Pulse Box with Cables (Series 3)

    • WH140005 Whirlpool Dryer Gen 2

Reader Cable with Coin Slide

    • WH140006 Whirlpool Neutral Wire)

Connections Illustration

AS140007  Whirlpool Dryer Pulse Box with Cables (Series 3)

Before Installation

PLEASE UNPLUG LAUNDRY MACHINE PRIOR TO INSTALLATION OF HARNESS

Wiring Instructions

Relay Box Connection

Locate the relay connection cables from the electromechanical timer, as shown below on right image, on the machine. Remove the yellow, black, blue and red cables.  

A motor assembly with labeled terminals and connections for electrical wiring.

Then plug the machines cables, as shown below, into the relay pulse box according to corresponding colors.  

 

 

Then connect the harness’s white male spade from the pulse box into the Whirlpool’s neutral wire.  

If the relay box is connected correctly, the LED light near the relay box port will turn on.

Card Reader Connection

Plug card reader’s data cable into WH140008 ‘s into card reader connection

Coin Connection (If applicable)

Connect the female red and white spades into the coin slide’s connections, if keeping coin.

**If you do not have the connection shown in left image below, and you plan on keeping coin, you will need to order this coin slide part from Whirlpool.

Close-up of an ESD device showing components and a switch mechanism.

Card Reader Jumper

Readers out of the box, will have the jumper set to “A” side. When using Whirlpool, this must be moved over to the “B” side. See “Additional Information” section for jumper identification on different KioSoft readers.

The jumper’s pins need to be horizontal and not vertical. The jumper has two parts, each with two pins. Make sure both pieces are moved closer to the right “B” side. Example image above shows an Ultra LX reader’s jumper moved to the “B” side.

Additional Information

Pulse Port Identification on KioSoft readers