Document Overview
The objective of this document is to cover how to setup a Whirlpool laundry machine with and without coin usage. This document goes over the wiring of a Whirlpool machine with connection kit PK140002. Additionally, how to create CommonPulse profile in the Cloud Configuration Manager, used for programming the KioSoft card reader.
Parts List
Part Number | Part Name | Items Included |
PK140002 | CleanReader Installation Kit - Whirlpool Electromechanical - Dryer (excl. Ultra) |
Reader Cable with Coin Slide
|
Connections Illustration
AS140007 Whirlpool Dryer Pulse Box with Cables (Series 3)
Before Installation
PLEASE UNPLUG LAUNDRY MACHINE PRIOR TO INSTALLATION OF HARNESS
Wiring Instructions
Relay Box Connection
Locate the relay connection cables on the machine and remove them.
Then plug the machines cables into the pulse box according to corresponding colors.
Then connect the harness’s white male spade & neutral wire from the pulse box on to the machine.
If the relay box is connected correctly, the LED light near the relay box port will turn on.
Card Reader Connection
Plug card reader’s data cable into WH140008 ‘s into card reader connection
Coin Connection (If applicable)
Connect the female red and white spades into the coin slide’s connections, if keeping coin.
Card Reader Jumper
Readers out of the box, will have the jumper set to “A” side. When using Whirlpool, this must be moved over to the “B” side. See “Additional Information” section for jumper identification on different KioSoft readers.
The jumper’s pins need to be horizontal and not vertical. The jumper has two parts, each with two pins. Make sure both pieces are moved closer to the right “B” side. Example image above shows an Ultra LX reader’s jumper moved to the “B” side.
Creating a Universal Pulse profile
Please note when using a Universal Pulse profile:
You must set the price and cycle time on the board.
Under CCM, in the Profile Builder, select the following for Machine Data
Select “Universal” tab then “Universal Pulse” tab
Select “Location” tab, and enter Location ID, Room ID and Site Code information. Enter Machine Profile, Products Pricing and Timing
Enter the desired Vend Price & Cycle Time. Value must match settings on machine board.
When using a Universal Pulse Profile, the Cycle Time is the amount of time the reader will not accept payment, once the machine is in use. Please make sure to change the cycle time as needed.
After, click on "Advance Options" enter the following pulse setting.
Pulse Output = Relay ON
Relay ON Time= 35
Leave all other setting as default
Once machine values are configured, click on “Site Data” and enter location information.
Site Code and Location ID must match the location in Location Management on Laundry Portal
For Location ID and Room#, you should enter the ones that you created previously
See image below regarding Site Data’s field values.
Location ID
Site Code
Room Number
Each room will get its own profile.
Non-Network
This should be enabled any time a modem is not present in the room.
Card Holder
Hide Label
This will hide the machine number on Connect and Elevate readers
If applicable, for Payment Options, ensure you select the payment methods for the desired location.
Finally, select “Save Profile” from the drop-down menu and click “Save”
Enter “Custom Text” for easier identification in the KioSoft Laundry Manager Application.
Example of Custom Text Label: Location Name RM1 MACHINECONTROL Dryer [225/45mins]
Additional Information
Pulse Port Identification on KioSoft readers | |
Solo, Connect, & Elevate | |
Ultra LX /LX Pro | |
Ultra VXT |
Jumper Identification on KioSoft readers | |
Solo, Connect, & Elevate | |
Ultra LX /LX Pro | |
Ultra VXT |