Document Overview
The objective of this document is to cover how to connect a KioSoft card reader to a Maytag MFR30 PD model laundry machine. This document goes over the wiring of an MFR with connection kit PK130021. Additionally, how to create a the machine’s profile in the Cloud Configuration Manager, used for programming the KioSoft card reader.
Parts List
Part Number | Part Name | Items Included |
PK130021 | Maytag MFR Washer With Coin Kit |
|
Harness Illustration
WH130029-Maytag MFR Washer With Coin Cable
WH120006-ACA Power Washer Cable & PP000003-Wire Tap Splice
PS100007-Power Adaptor, 12V for Reader
Programming Machine Board
MRF30 Machine must be set to coin and debit mode. This ensures cycle status, otherwise reader will not sense cycle has stopped. NOTE: Menu options may vary, please consult the Owner’s Manual, programming section for your laundry machine.
To programming the machine, enter service mode by turning the service key to switch from “RUN” mode to “SERVICE”. Once, in-service mode, the main menu will appear on the display, example image below:
Use the follow chart below to navigate main menu.
Arrow Right | Arrow up | Escape |
|
|
|
Arrow Left | Arrow Down | Enter |
|
|
|
Go to “Pricing Menu”, then “General” (Set-up of Pricing related functions)
Finally, change payment selection to “Coin & Card”
Before Installation
PLEASE UNPLUG LAUNDRY MACHINE
PRIOR TO INSTALLATION OF HARNESS
Wiring Instructions
Coin Connections
Original Maytag MFR terminal block connections shown below for reference.
Coin Out to Machine
Remove machine terminal block clear tab connectors and connect to the harness’s female spades according to the following directions:
Machine green (COIN1) cable to harness green cable
Machine blue cable to harness blue cable
Machine red cable to harness red cable
Coin In to Terminal
Machine terminal red to harness green cable
Machine terminal blue to harness black cable
Green cable (COIN2) with clear tab remains on terminal
Machine terminal yellow to harness white cable
Serial Connection
Plug in the serial connector, orange and black cable, from WH130029 to the laundry machine’s motherboard, labeled as L1. Example image of control board below, control board colors may vary.
Power Connections
Connect the AC Power Adaptor PS100007’s 2 pin cable male cable into WH130029’s 2- pin female power connector.
Afterwards, connect PS100007’s brown and blue 2 pin connector into WH120006’s black and white cable.
Then connect WH120006’s black and white cable using the blue tabs to splice into the laundry machine for power.
NOTE: Please consult the Owner’s Manual, under the installation section, before fully connecting WH120006 & PS100007 Power Adaptorto your laundry machine. Depending on the machine model and voltage, connections may vary. For guidance, PS100007 Power Adaptor accepts a wide input from 100- 240 V – 50-60HZ 0.8A and output of 12V.
For example: In the reference images shown below, the power line is located on the top left side of the machine, shown in a red circle on see image below. WH120006’ s black cable would be spliced into machines' black cable. Then WH120006’s white black cable would be splice into machines' white cable.
Card Reader Connection
Plug card reader’s data cable into WH1P0002’s card reader connection.
Card Reader Jumper
Readers out of the box, will have the jumper set to “A” side. For the MFR30, this must be moved over to the “B” side. See “Additional Information” section for jumper identification on different KioSoft readers.
The jumper’s pins need to be horizontal and not vertical. The jumper has two parts, each with two pins. Make sure both pieces are moved closer to the right “B” side. Example image above shows an Ultra LX reader’s jumper moved to the “B” side.
Creating a Universal Pulse profile
Note: When using Universal Pulse Profile in CCM, readers must be 2.71.0 or higher & under KLM app reader needs to be programmed as a “CleanReader” not “Ultra”.
Under CCM, in the Profile Builder, Select “Universal” then “Universal Pulse”
Enter desired information under the following tabs: ”Location”, ”Machine Profile” and ”Products, Pricing
and Timing”.
Once completed, under the “Pulse” tab enter the following pulse setting for a MFR30:
Output = RelayPulse
Output Pulse Gap = 100 Pulse Polarity = Idle Open Output Pulse Duration = 50
Laundry Available Signal = Low
Proceed to fill out the following tabs as needed “Payment Types and Methods” and “Data Processing”. Finally, select “Save Profile” from the drop-down menu and click “Save”
Enter “Custom Text” for easier identification in the KioSoft Laundry Manager Application.
Example of Custom Text Label: Location Name RM1 MFR30PD [5.50]
Additional Information
Jumper Identification | |
Solo, Connect, & Elevate | |
Ultra LX /LX Pro | |
Ultra VXT |