Document Overview
The objective of this document is to cover how to setup a Whirlpool (Green Button) washing machine with and without coin usage. This document goes over the wiring of a Whirlpool (Green Button) washer with connection kit PK140003. These instructions apply specifically to the Whirlpool washer model featuring a prominent green button on its display, as shown in the images below.
Please note: These instructions are for washers only and do not apply to dryers.

Parts List
Part Number | Part Name | Items Included |
PK140003 | Reader Installation Kit - Whirlpool Electronic Start (Green Button) |
|
Connections Illustration

WH140008 Whirlpool Washer Cable with Coin Slide (Electronic) and AS140003 Emech Relay Interface Board, Washer (Series 1)

WH120006 - ACA Power Washer Cable with PP000003 - Wire Tap Splicer (x2)
Before Installation

PLEASE UNPLUG LAUNDRY MACHINE PRIOR TO INSTALLATION OF HARNESS
Wiring Instructions
Coin Pulse Connections
Connect harness WH140008’s 2-by-2 male coin cable connector into machine female 2-by-2 connector from the coin.
NOTE: If this is not done the machine will not pulse and will not start.

***If you have coin spade connectors instead, please plug in the KioSoft harness’s female red and white spades into the coin slide’s connections.
|
J15 (Single Red Lead) Connection
On the machine board, located the J15 connection. The J15 connection will be right next to the J3 connection as shown below. Note: In whirlpool wiring diagram this is labeled as "J15-4 RED lock switch"

Take the single lead red wiring on WH140008 and splice the cable into the machine’s red cable on J15 connection.

Power Connection
Locate J7 on the machine board, where the black and white power cables are connected.

Using the blue tabs included in the kit, splice WH120006 into the machine’s matching cable colors; black to black and white to white.

Then plug in WH140008’s female power connection, black and white, into WH120006’s male connector.

Card Reader Connection
Plug card reader’s data cable into WH140008 ‘s into card reader connection

Card Reader Jumper
Readers out of the box, will have the jumper set to “A” side. When using Whirlpool machines with the readers, this must be moved over to the “B” side.
See “Additional Information” section for jumper identification on different KioSoft readers.

The jumper’s pins need to be horizontal and not vertical. The jumper has two parts, each with two pins. Make sure both pieces are moved closer to the right “B” side. Example image above shows an Ultra LX reader’s jumper moved to the “B” side.
Additional Information
Pulse Port Identification on KioSoft readers | |
Solo, Connect, & Elevate |
|
Ultra LX /LX Pro |
|
Ultra VXT |
|
Jumper Identification on KioSoft readers | |
Solo, Connect, & Elevate |
|
Ultra LX /LX Pro |
|
Ultra VXT |
|