Adjust Tray Height

Prev Next

Adjust Tray Height

  1. Move out the tray

1) Pull up the tray fixing buckle.

2) Hold up the front end of the tray, then pull it out.

3) Cut the ribbon fastening the cable at the back side of the tray.

4) Unplug the tray cable connector.

5) Take out the tray.

  1. Adjust the height of the slide rails

1) Remove the tray slide rail screws at both sides.

2) Un hook the slide rails from the holding holes.

Note: The distance between two contiguous holding holes is 2cm.

3) Adjust the slide rails to the proper height and fasten with screws.

4) Install back the tray.

Note: The height of the slide rails at the two sides should be the same.

  1. Program the Tray Height and Elevator

Login the Android management system with admin account. Navigate to “Machine Debugging” section by the main menu at the left side. In this section you can test the movement of the elevator, adjust the elevator height to each layer, test if the layer height is collaborated with the movement of the elevator, etc.

Layer setting: set how many layers are installed and configured in the machine. Usually used when you add layers to or remove layers from the machine.

Layer height setting

Layer height adjustment and testing

  • Select the layer to be tested

  • input the height (mm)

  • press “Set up” button

  • press “Layer height test” button

  • the elevator will move to the height as configured.

Elevator testing:

  • Press “up” button, the elevator will move upward;

  • Press “Down” button, the elevator will move downward;

  • Press “Cease” button, the elevator will stop moving;

  • Press “Return to origin” button, the elevator will return to the initial position.

  • Adjust the elevator movement speed by pressing the speed selection buttons.

Complete machine calibration test

  • Press “Testing All Layers” button to test the calibration of elevator with all layers of slots in the whole machine.