Status Query Settings
Query parameters: user can select a specific parameter from the list, then click “Query” to see its value.
Setting parameters: user can select a specific parameter from the list, then click “Set up” to change its value. Given this section belongs to engineering menu, not recommend to change without professional guidance.
Machine status: similar feature as mentioned in section Query Fault.
Query pickup door mode: to query the status of the pickup door.
Set pickup door mode: set the pickup door mode based on the actual situation.
|
|
Elevator & Slot Height Adjustment (Location settings)
In this section you can test the movement of the elevator, adjust the elevator height to each layer, test if the layer height is collaborated with the movement of the elevator, etc.
Layer setting: set how many layers are installed and configured in the machine. Usually used when you add layers to or remove layers from the machine.

Layer height setting
Elevator testing:
Press “up” button, the elevator will move upward;
Press “Down” button, the elevator will move downward;
Press “Cease” button, the elevator will stop moving;
Press “Return to origin” button, the elevator will return to the initial position.
Adjust the elevator movement speed by pressing the speed selection buttons.
Layer height adjustment and testing
Select the layer to be tested;
input the height (mm);
press “Set up” button;
press “Layer height test” button;
the elevator will move to the height as configured.
Complete machine calibration test
Press “Testing All Layers” button to test the calibration of elevator with all layers of slots in the whole machine.
|
|
Voltage & Current Setting (current setting)
In this section you can set minimum/maximum voltage and current of the elevator, anti-theft plate and pickup door. Given this part belongs to engineering menu, not recommend to change without professional guidance.
|
|
|