Summary
How to Create a Pulse Profile for Maytag MXR washer using PK130021.
Issue
How to Create a Pulse Profile for Maytag MXR washer using PK130021.
Environment
Maytag MXR, Profit Plus, CCM
Resolution
|
---|
First let’s login into Washboard.
Once we’ve logged into the account’s Washboard, let’s search for CCM (Cloud Configuration Manager).
Now, in the Profile Builder, Select Universal then Universal Pulse
Moving forward, you will be clicking on each tab starting with Location and providing the information for the configuration. This information must match the data previously entered in your vendors portal Location Management
In the Machine Profile tab, change the following.
Machine Type: Washer
Reader Mode: Value
Pocket Configuration: Single
The Audio Visual tab can be left as default.
In the Products, Pricing and Timing tab, enter desired pricing.
NOTE: Time & Price must be set on the machine board as well.
Choose the basic pricing and enter the desired values.
Adjust the Run Time, average wash time is 25 mins.
Top-Off should be disabled.
Once completed, under the Pulse tab enter the following pulse setting for a Maytag MXR machine.
Output Type: Coin Pulse
Pulse Polarity: Idle Open
Output Pulse Gap: 100ms
Output Pulse Duration: 22ms
Proceed to fill out the following tabs as needed in the Data Processing tab.
For Surface readers (Prime, Connect, Solo using mobile app and/or laundry card):
Leave the Data Processing tab as Default.
Only for Ultra Readers (Credit Card):
Payment Gateway Option: (from VAR sheet provided)
POS ID: (from VAR sheet provided)
Aut Code: (from VAR sheet provided)
Auth Factor: (from VAR sheet provided)
Work Mode: Retail (unless otherwise specified)
WiFi SSID: techtrex (unless otherwise specified)
In the Payment Types and Methods tab, enter the desired payment options and change "SiteCodeCheck” to Enable.
Finally, save the profile.
Note: The card reader’s AB jumper must be set to B side when using the (relay pulse) settings shown above.