When using a common pulse or universal pulse profile on Encore Dryers, you must set the settings on the machine board so they match what you put on the profiles.
Issue
When using a common pulse or universal pulse profile on Encore Dryers, you must set the settings on the machine board so they match what you put on the profiles. Please, follow the steps below on how to set the value of Coin1, Pricing Parameters, Cycle Times, Top Off Time, and MAX Dry Time.
Environment
Encore Dryer
Resolution
Programming the Machine Board
To enter programming mode on the Wascomat Crossover machine, press the red button on the back of the board. NOTE: Do not hold for more than 5 seconds, this will factory reset the board. When the button has been pressed, the board will display “8.8.8.8.”
Press “Start” and the machine's display will show “SE”. From here you can use the “No Heat” button (Up) and the “Low Heat” button (Down) to navigate through the machine parameters.
Once you are at the parameter you need to change, press “Start” to adjust the value. The following parameters, shown as numbers below, will need to be changed to match the CommonPulse profile used to set up the KioSoft reader.
COIN1 Value: 031
• Default is 25 in both the machine and profile.
• Range=”0.00”-”9.99”, omit decimal if register 030=”1”.
• Please note: Value of COIN1 used as top-off pricing.
Pricing parameters:
• 040 Amount to start (ATS) for High heat program (range=0.00-9.99, default= 0.00).
• 041 Amount to start for Medium heat program (range=0.00-9.99, default=0.00).
• 042 Amount to start for Low heat program (range=0.00-9.99, default=0.00).
• 043 Amount to start for No heat program (range=0.00-9.99, default=0.00)
Cycle Times:
• 044 Time for ATS for High heat(range=1-90, default=40).
• 045 Time for ATS for Medium heat(range=1-90, default=40).
• 046 Time for ATS for Low heat(range=1-90, default=40).
• 047 Time for ATS for No heat(range=1-90, default=40).
Top off Time (in minutes):
• 048 Time for additional coin or push for High heat (range = 0-90, default = 6).
• 049 Time for additional coin or push for Medium heat (range = 0-90, default = 6).
• 050 Time for additional coin or push for Low heat (range = 0-90, default = 6)
• 051 Time for additional coin or push for No heat (range = 0-90, default = 6).
Max Dry Time:
• 052 Max drying time - High (range 1-90, default = 90).
• 053 Max drying time - Medium (range 1-90, default = 90).
• 054 Max drying time - Low (range 1-90, default = 90).
• 055 Max drying time – No Heat (range 1-90, default = 90)