Document Overview
The objective of this document is to cover how to setup a Alliance ACA (Quantum Gold) controlled machine. This document goes over the wiring of an ACA (Quantum Gold) with connection kit PK120068. Additionally, how to create the machine’s profile in the Cloud Configuration Manager, used for programming the KioSoft card reader.
Parts List
Part Number | Part Name | Items Included |
PK120068 | Reader Installation Kit - Alliance (Quantum/ACA - C,N,X Models) |
|
Harness Connections Illustration
WH120011 ACA harness with Coin Drop Connector
Before Installation
PLEASE UNPLUG LAUNDRY MACHINE PRIOR TO INSTALLATION OF HARNESS
Changing machine board to SERIAL mode
With the ACA machine off, verify the machine is set to “Serial Payment System” mode by looking at the dipswitches on machine board. Dipswitches are located on the bottom left of the board. Only dipswitch 3 needs to be on, all others are off. See example of machine board images below.
If the machine is left on while making changes to the dipswitches, the changes may not take effect. Power cycle the machine afterwards.
Wiring Instructions
Remove front panel screws of the machine to reveal ACA motherboard. Example of machine board shown below.
Serial Connection
Connect the WH120011’s card reader serial cable to the machine board, located on the top left-hand side.
Power Connection
There are two methods for getting power from machine, depending on the type of reader.
For Connect & Solo Readers, use the “H10” on the ACA motherboard and WH120020, included in harness kit. H10 connection on the board is located above the dipswitches.
Connect Kiosoft harness female power cable (black & white) to male connection on WH120020.
Then connect the female end of the WH120020 cable to the “H1” connection on the
board.
For Ultra reader, reader will receive power using the transformer with additional parts: AC/Adaptor PS100007 with WH120021, and WH120015
Disconnect the machine’s transformer connection (see image).
Connect machine’s male transformer connection to WH120021’s female power connection. Then WH120021’s male power connection to machine’s female transformer connection.
Connect the third cable (male connector) from WH120021 to the AC/Adaptor’s female connector (brown & blue) and the other end of the AC adaptor cable (male connector, red and black) to WH120015 female connector.
Finally, connect WH120015 into WH120011 harness’s cable (black and white).
Coin Connection, If appliable
Connect the machine's coin cable into WH120011’s 3-pin male coin cable (red, black & white).
Reader Connection
Plug card reader’s data cable into harness WH120011’s card reader cable
Creating an ACA profile
Under CCM, in the Profile Builder:
Select the following for Machine Data
Select Manufacturer as “Alliance”
Select Machine Control Type as “ACA”
Select Machine type:
Please note: The ACA laundry machines from year 2020 need an ACA MAX profile.
With an ACA MAX profile, the reader is pulling the vend price from the machine board. You must set the desired vend price on the machine board.
After, click on "Advance Options" and configure machine fields (vend price, time, etc.) as needed.
Once machine values are configured, click on “Site Data” and enter location information.
Site Code and Location ID must match the location in Location Management on Laundry Portal
For Location ID and Room#, you should enter the ones that you created previously
See image below regarding Site Data’s field values.
Location ID
Site Code
Room Number
Each room will get its own profile.
Non-Network
This should be enabled any time a modem is not present in the room.
Card Holder
Hide Label
This will hide the machine number on Connect and Elevate readers
If applicable, for Payment Options, ensure you select the payment methods for the desired location.
Finally, select “Save Profile” from the drop-down menu and click “Save”
Enter “Custom Text” for easier identification in the KioSoft Laundry Manager Application.
Example of Custom Text Label: Location Name RM1 ACA Dryer [225/45mins]