ID | Error Code | Issue Description | Solution |
Cloud Based Card Errors | ANF | Account not found | Bind the card to the account. You can follow one of the two ways to fix the issue: 1) Vendor admin can go to vendor portal -> User Management. Locate the customer info and click on “Edit”. Then enter the laundry card number # and click to save changes. 2) The customer can open Cleanpay Mobile app -> Account -> Update Laundry Card. Enter the LC number and CVC (that can be found at the backside of the card). |
E001 | Get price failed | 1. Check if the cloud card is bound to the account 2. Check if the account is registered | |
E002 | Deduct money failed | 1. Check if the cloud card is bound to the account 2. Check the third-party response log | |
E003 | Start failed | Automatic reversal, nothing needs to be done | |
E004 | Start time out | User needs to start machine within 1 minute of successful payment, some may require within 90 seconds Note: “E004” will be displayed at the terminal side, while “Start Failed”/”Can’t Start Machine” will be shown on mobile app. | |
E005 | Price changed | Automatic reversal, nothing needs to be done | |
E007 | Network is unavailable | Use KioSoft modem or check network | |
E008 | CJSON Parse (WB returns error text) | Need to fix the data responded from the server. Please contact KioSoft team for fixing the issue, i.e. by closing Cloudflare filter. | |
E009 | Error https | The error code may appear under the following scenarios: 1) No data response. Solution: Need to fix the data responded from the server. Please contact KioSoft team for fixing the issue, i.e. by closing Cloudflare filter. 2) Server overloaded. Solution: re-arrange the schedule to re-start the readers in batched. i.e. if we have 200 readers in total. Restart 100 readers in the morning and restart the rest devices in the afternoon. 3) No Internet available for the reader. Solution: check the internet and ensure it’s well-connected. | |
E010 | Get Random Key failed | Use KioSoft modem | |
E012 | Reversal failed | Chek internet | |
E013 | No KioSoft modem | Use KioSoft modem | |
E014 | No Modem | 1.Use KioSoft modem; 2.Check that the SSID to be connected matches the router SSID | |
E015 | Account is disabled | Go to server->Vendor Portal->Location Management to enable the account | |
E017 | Balance is negative | Balance is insufficient. Please change a new card. | |
E016 | Other errors | / | |
E018 | Insufficient points | Change the payment method to balance | |
E019 | Encrypt fails. | Encrypt key is incorrect. Generate a new key again, i.e. by re-starting the reader. | |
Other Codes | last 4 digits of SN | for virgin readers (display prior to the reader’s setup) | / |
D-62 | Waiting for Dep Key (during reader’s setup) | Tap Dep Key Only TechTrex can perform this step. Older versions may display D-62. | |
F-62 | Waiting for Reader Key Card (during reader’s setup) | Tap Reader Key Card | |
F-61 | Waiting for Machine Setup Card (during reader’s setup) | Tap Machine Programming Card | |
F-60 | Waiting for Site Card (during reader’s setup) | Tap Site Card | |
E-51 | Site Code between laundry card and Reader do not match | Laundry card and reader need to be programmed to the same site code | |
E-98 | Value Exceeded | Reinput the value under 99.99 | |
Lo | Balance on laundry card is lower than vend price | All readers in a laundry room should have a max value that is equal to or higher than the max value programmed in the Kiosk. | |
cErr | Cannot communicate with machine | Check the connections to the machine | |
rEbt | Start to Reboot | / | |
Er13 | Network Testing, all WiFi signal is 0 | Check Router or Internet | |
bUSy | Start to do NMS | / | |
SUCC | NMS/TMS update successfully | / | |
FAIL | All function failed | / | |
-dL- | Start to download or receive pkg | / | |
dlod | TMS retry | / | |
rSEt | Factory reset | / | |
rEdy | Readers receive any command from app, reader will show rEdy | / | |
E-44 | Different vendor after tapping laundry card | 1.Use the laundry card belonging to the vendor that the machine belongs to; 2.It could also be that the card was removed too quickly, try to remove the card more slowly | |
New Error Code | E-20 | When double tap, two cards are not the same card. | Use the same card |
FREE | deduct points, show free cycle | / | |
UnPu | Universal Pulse | / | |
nGD | MGD | / | |
TITN | TITANIUM | / | |
ndc | MDC | / | |
MIDS | ST_MIDAS | / | |
qUAn | CENTURION/Quantum | / | |
L6 | ST_LG | / | |
COin | COINDROP | / | |
ntAG | MAYTAG | / | |
CrO5 | CROSSOVER/CROSSOVER_20/CROSSOVER_ENCORE | / | |
Conp | COMPASS/COMPASS_W620 | / | |
E-Le | remote profile length too large | The length of profile exceeds the maximum limit, check profile. | |
-btU- | bt update | / |
Sev Field Issue
LG Machine prices go from $1.75 to $0.10
Bug No. | #23620 |
Description | The LG machine was set for a $1.75 vend price, while a few days later, the price changed to $0.10. |
Root Cause | The old profile from CCM is incorrect. |
Solution | Set up new profiles. |
TWSystem Room Status Not Updating
Bug No. | #25977 |
Description | There are 16 readers at the location but they are not all shown up in the Room Status page. |
Root Cause | The reader was artificially updated to CRPS, but the CRPS code doesn’t connect to the router. |
Solution | Use the correct application. |
Unable to start the machine
Bug No. | #25152 |
Description | Start the machine with a mobile app; the reader beeps once, but the machine is not started. |
Root Cause | The offline trans record is full, and the too-old version reader doesn’t support factory reset to clear the EEPROM. |
Solution | Upgrade readers to a higher version |
Setup Failed with Laundry Signal Box Enabled in Universal Pulse
Bug No. | #28321 |
Description | Create a CCM profile in CleanStore, set hardware to Laundry Signal Box, set in-use signal to high or low, save the profile, and inject profile via KLM, the profile injection failed. |
Root Cause | This is how it is designed. |
Solution | Upgrade the reader to a version higher than 1.29.2 |
When starting LG machine, it will prompt a price of $0 in the app and unable to start the machine
Bug No. | #23621 |
Description | When the coin amount is greater than or equal to the vend price, do not press the start button, and then use the APP to start, the phone will prompt the price is 0. |
Root Cause | After the reader sends pulse, the reader will set the Machine Status to busy. If the laundry machine does not change from idle to busy, the reader will not return idle. |
Solution | Upgrade the reader to version 1.27.4.2 |
Large charge on mobile transaction
Bug No. | #25404 |
Description | Use Hercules CP Mobile to start a machine, but the user will be randomly charged $81.92, which should be expected to be $2.25 or $2.50. |
Root Cause | Machine error |
Solution | Upgrade the reader to version 1.28.6.3 |
n01 not updated when the machine goes to in use without payment
Bug No. | #22722 |
Description | Create a common pulse or universal pulse profile with in-use signal set to high or low, set up the reader with the profile, and then start the machine manually, the room status and N01 show “machine available”, instead of showing “cycle started”. |
Root Cause | When Prime Pro or Elevate Card Connect directly detected the change from idle to busy, the uploaded N01 had a Remaining Time of 0 |
Solution | When the machine status changes from idle to busy, upload the Remaining Time of N01 according to the profile configuration |
Reader failed to start with the laundry card
Bug No. | #23453 |
Description | The reader is set up to accept the laundry card payment, when tapping the laundry card on the reader, the reader flashes error light and beeps and fails to start, only works intermittently. |
Root Cause | The factory uses the wrong chip for the reader, for the reader with AT chip works well, only the reader with GD chip doesn’t work. |
Solution | Modify usart.o to the Flash high-speed area. |
Whirlpool relay box causes the machine to run when overheated
Bug No. | #26032 |
Description | The Whirlpool dryer runs continuously long after the cycle finished, which is caused by the overheating relay box. |
Root Cause | The optocoupler chip slowed down after heating. The serial timing bit became too narrow to be recognized by the AT CPU. |
Solution | Add 470-ohm resistor to the yellow wire on WH140005 cable. Make sure you have heat shrink around the resistor to provide insulation. |
MLG27PR UI board failed after the reader installed
Bug No. | #28022 |
Description | After installing the readers, the dryer momentarily lost power to the UI. However, the outlet supplies steady power, and the power delivery components in the dryer also work normally. Also, it witnessed that the price was reverted to the default value but the UI board is not damaged. |
Root Cause | Not found. |
Solution | Upgrade the reader to version 0100.296.002.007. |